Product Description
The Capillary Kit Viper for UltiMate 3000 RSLC systems is a remarkable solution for advanced chromatography setups. This scarce offering is a paragon of precision, minimizing dead volume for preeminent chromatographic accuracy and performance. Designed for manual, tool-free installation, the kit supports high-pressure tolerance up to 1300 bar and is compatible with LPG or DGP pump modules. Its pre-assembled, finger-tight connections allow seamless advance purchase solutions for hot deal seekers in HPLC/UPLC plumbing. Supplied complete with reusable components and protective packaging, its a premium kit for demanding scientific environments.
Versatile Application and Superior Features
Engineered to excel with common HPLC solvents including acetonitrile, methanol, water, and buffer solutions, the Capillary Kit Viper boasts zero-dead-volume connections and reusable, tool-free fittings. Its application media spans nano- and microbore flow ranges and is suitable for rigorous chromatographic systems. Other features include stainless steel tubing, PEEK Viper fittings, and various capillary lengths, empowering users in research, pharma, or analytical labs with outstanding adaptability for high-pressure HPLC or UPLC plumbing.
Domestic Market and Purchase Convenience
Available for direct purchase within India, the Capillary Kit is supplied with certifications and can be shipped on advance Purchase Order terms. The kit supports drop-off to laboratories, research centers, and industry suppliers nationwide. With robust protective packaging, buyers enjoy confidence in every delivery. Approved for certified HPLC/UPLC use, this product facilitates swift domestic transactions, making it the trusted choice for manufacturers, exporters, distributors, and traders seeking reliable, top-tier plumbing solutions.
FAQs of Capillary kit Viper for UltiMate 3000 RSLC system with LPG or DGP pumps:
Q: How do I install the Capillary Kit Viper for the UltiMate 3000 RSLC system?
A: Installation is straightforward and tool-free, thanks to pre-assembled Viper finger-tight connections. Simply follow the instruction manual provided in the kit for secure and precise setup.
Q: What benefits does zero-dead-volume connection offer in chromatography?
A: Zero-dead-volume connections minimize sample dispersion and improve analytical accuracy, resulting in sharper chromatographic peaks and superior separation efficiency.
Q: When is it recommended to use the Capillary Kit Viper with LPG or DGP pumps?
A: This kit is ideal for high-precision HPLC/UPLC systems using LPG or DGP pumps, especially when minimizing dead volume and maintaining high-pressure tolerance are critical for optimal results.
Q: Where can the Capillary Kit Viper be used?
A: Its suitable for laboratories, research facilities, pharmaceutical environments, and analytical settings utilizing Dionex UltiMate 3000 RSLC systems with LPG or DGP pumps.
Q: What application media are compatible with the kits capillaries?
A: The Capillary Kit Viper is compatible with a wide range of HPLC solvents including acetonitrile, methanol, water, and buffer solutions, supporting diverse chromatographic requirements.
Q: How is the kit shipped in India and what payment terms are available?
A: The kit can be shipped via drop-off or courier within India upon advance Purchase Order. Certified packaging ensures safe delivery, and standard payment terms for traders and suppliers are accepted.