08045815658
info@nationalsales.co
Change Language
DELUXE TABLE TOP BENCH PH METER MODEL - EUTECH PH 2700

DELUXE TABLE TOP BENCH PH METER MODEL - EUTECH PH 2700

Product Details:

  • Response Time <1 second
  • Operating Voltage 230V AC
  • Display Type Large custom backlit LCD
  • Resolution pH: 0.01 pH, ORP: 1 mV, Temp: 0.1C
  • Mounting Type Table Top
  • Temperature 5C to 45C
  • Accuracy pH: 0.01 pH, ORP: 1 mV, Temperature: 0.3C
  • Click to view more
X

DELUXE TABLE TOP BENCH PH METER MODEL - EUTECH PH 2700 Price And Quantity

  • 3-4 Piece

DELUXE TABLE TOP BENCH PH METER MODEL - EUTECH PH 2700 Product Specifications

  • Manual / Auto
  • 230V 10% AC, 50 Hz
  • Laboratory, Industrial, Research
  • 1.3 kg
  • RS232C output
  • 50 Hz
  • Deluxe Table Top Bench pH Meter
  • 5C to 45C
  • Table Top
  • pH: 0.01 pH, ORP: 1 mV, Temperature: 0.3C
  • 230V AC
  • pH: 0.01 pH, ORP: 1 mV, Temp: 0.1C
  • pH, mV (ORP), and temperature measurements in laboratory settings
  • Large custom backlit LCD
  • <1 second

DELUXE TABLE TOP BENCH PH METER MODEL - EUTECH PH 2700 Trade Information

  • 3-4 Piece Per Day
  • 3-4 Week

Product Description

MODEL NO : EUTECH PH 2700

PRODUCT FEATURES :

OVERSIZE SCREEN WITH LARGE FONTS YET COMPACT THE NEW EUTECH PH 2700 OFFERS AN EASY TO READ SCREEN THAT SAYS MORE. VIEW PH OR ORP READINGS, WITH TEMPERATURE, ELECTRODE STATUS, CALIBRATION POINTS, DATE AND TIME ALL AT ONCE!

UP TO 6-POINT CALIBRATION WITH AUTO-BUFFER RECOGNITION

QUICK, EASY ELECTRODE DIAGNOSIS WITH MULTIPLE PH SLOPES AND OFFSET DISPLAY

NON-VOLATILE MEMORY HOLDS UP TO 500 DATA POINTS TIME AND DATE-STAMPED FOR GLP COMPLIANCE

CALIBRATE WITH UP TO 5 CUSTOM PH BUFFERS USE ANY PH VALUES THAT ARE >=1.0 PH UNIT APART

CAL-DUE ALARM NO MORE OUT-DATED CALIBRATIONS!

AUTO-LOGGING FUNCTION FOR CONVENIENT CONTINUOUS MONITORING

PASSWORD PROTECTION FOR SETUP AND CALIBRATION

APPLICATIONS:

EDUCATIONAL: USEFUL FOR MOST LABORATORY, ECOLOGICAL STUDIES AND OTHER APPLICATIONS

LABORATORY: ENVIRONMENTAL STUDIES, CHEMICAL LABS, TITRATIONS AND QUALITY ASSURANCE TESTING, WHERE GLP 
DATA-MANAGEMENT IS REQUIRED. USE IN ALL TYPES OF FOOD PROCESSING.

SPECIFICATIONS:

PRODUCT SPECIFICATION

DESCRIPTION

PH

 

RANGE

-2.000 TO 20.000 PH

RESOLUTION

0.1 / 0.01 / 0.001 PH

ACCURACY

0.002 PH + 1 LSD

CAL. POINTS

UP TO 6 PRESET OR 5 CUSTOM

BUFFER SETS

USA, NIST, DIN, USER 1, USER 2, CUSTOM

ORP

 

RANGE

2000.0 MV

REL. MV RANGE

2000.0 MV

RESOLUTION

0.1 MV

ACCURACY

0.2 MV

TEMPERATURE

 

RANGE (METER)

0.0 TO 100.0C / 32.0 TO 212.0F

RESOLUTION

0.1C / 0.1F

ACCURACY

0.3C / 0.5F

COMPENSATION

ATC / MTC

POWER REQUIREMENTS

9 V DC ADAPTER, 1.3 A (100/240 VAC, SMPS)



Enhanced Measurement Precision

Experience highly accurate pH, ORP, and temperature measurements with a resolution of 0.01 pH, 1 mV, and 0.1C. The Eutech PH 2700s advanced electronics and automatic temperature compensation ensure consistent results even under varying lab environments.


User-friendly Controls and Data Management

Operate the pH meter effortlessly with its large backlit LCD interface and intuitive menu navigation. Store up to 500 data sets, all GLP-compliant, and export data easily via the RS232C output for thorough research traceability and analysis.


Reliable Durability and Versatility

Built for daily laboratory demands, the PH 2700 boasts premium construction, a stable table-top mount, and an adjustable electrode stand. Whether used for research, industrial processes, or educational settings, it adapts seamlessly to diverse measurement needs.

FAQs of DELUXE TABLE TOP BENCH PH METER MODEL - EUTECH PH 2700:


Q: How does the automatic pH buffer recognition function operate in the Eutech PH 2700?

A: The Eutech PH 2700 automatically identifies standard buffer solutions (USA, NIST, DIN) during calibration, ensuring correct calibration points are recognized without manual input, which improves accuracy and efficiency in your workflow.

Q: What is the process for storing and managing measurement data on this meter?

A: The device can store up to 500 data sets internally. Each data entry is logged with GLP-compliant information, allowing easy tracking and retrieval. Data can be exported via the RS232C interface for further analysis on a computer.

Q: When should I use the manual versus auto control mode on the pH meter?

A: Manual mode is ideal when precise user intervention is needed during calibration or measurement. Auto mode enables automatic recognition and adjustments, best for routine measurements or high-throughput environments where efficiency is key.

Q: Where is the Eutech PH 2700 primarily used and what are its typical applications?

A: This pH meter is designed for laboratory table-top use and is widely implemented in research labs, industrial quality control, and educational settings across India. Its versatility allows for reliable pH, mV (ORP), and temperature analyses.

Q: How does the adjustable electrode arm benefit laboratory work?

A: The included adjustable electrode arm stabilizes the combined glass electrode over samples, minimizing handling errors and ensuring consistent placement during repeated measurements, enhancing overall accuracy and operator comfort.

Q: What are the advantages of the Good Laboratory Practice (GLP) compliance in this meter?

A: GLP compliance means measurement data are recorded with essential audit information (such as date/time, calibration history), supporting traceability and quality assurance processes critical for regulated laboratory environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'PH Meter' category