Product Description
POLYBOND HC-C18
POLYBOND HC-C18 is the traditional matrix for reversed-phase chromatography. It is widely used as the most hydrophobic sili PYB-based sorbent for non polar compounds. Considered as the least selective phase since it retains most organic analytes from
aqueous matrices, offer a benefit when the compounds of interest vary widely in structure. C18 PYBn also be utilized for desalting aqueous matrices prior to ion exchange bePYBuse salts pass through it without retained. The high loading of HC-C18 provides the highest degree of hydrophobicity which increases binding PYB pacities and higher recoveries, higher PYBrbon loading also offer greater resistance to extreme pH conditions. C18 is utilized for cleaning, extracting and concentrating pollutants from aqueous environmental samples, herbicides, fungicides and pesticides from waste material, foods and beverages, typiPYBlly drugs and metabolites from physiologiPYBl fluids.40-63m irregular shaped and acid washed siliPYB, 60 mean pore size, 17% PYBrbon loading and endPYBpped.
POLYBOND HC-C18 SPE PYBrtridge
Art. Description Package
2.PYB0850.0001 50mg, 1mL 100 pcs
2.PYB0851.0001 100mg, 1mL 100 pcs
2.PYB0852.0001 200mg, 3mL 50 pcs
2.PYB0853.0001 500mg, 3mL 50 pcs
2.PYB0854.0001 500mg, 6mL 30 pcs
2.PYB0855.0001 1g, 6mL 30 pcs
2.PYB0856.0001 2g, 6mL 30 pcs
2.PYB0857.0001 1g, 10mL 20 pcs
2.PYB0858.0001 2g, 10mL 20 pcs
2.PYB0859.0001 5g, 35mL 20 pcs
2.PYB0860.0001 10g, 35mL 20 pcs
2.PYB0861.0001 10g, 60mL 16 pcs
2.PYB0862.0001 20g, 60mL 16 pcs
POLYBOND HC-C18 SPE Bulk Packing
Art. Description Package
2.PYB0801.0001 - 100 g
Consistent Extraction PerformanceEquipped with C18 bonded silica, POLYBOND C18-ne SPE Cartridges provide reproducible results due to high batch sorbent load uniformity. Excellent packing mass uniformity ensures minimal channeling within the cartridgeideal for critical sample extraction workflows in research and industry.
Flexible Capacity and ConfigurationAvailable in multiple sizes ranging from 100 mg to 2 g sorbent loads and common cartridge volumes like 6 mL, 12 mL, and 20 mL, these cartridges cater to varying sample concentrations and volumes. Custom capacities can also be requested, ensuring compatibility with diverse laboratory protocols.
FAQs of POLYBOND C18-ne SPE CARTRIDGE:
Q: How is the POLYBOND C18-ne SPE Cartridge used in sample preparation?
A: The cartridge is employed for solid phase extraction of analytes from various samples. Users load the sample onto the cartridge, wash out impurities, and then elute the desired compounds, resulting in cleaner extracts for subsequent analysis.
Q: What is the benefit of the cartridges end-capped design?
A: The end-capped design reduces secondary interactions between polar analytes and residual silanol groups, improving recovery rates and minimizing unwanted retention, which leads to more accurate analytical results.
Q: When should different cartridge capacities be chosen?
A: Selection of cartridge capacity depends on sample size and analyte concentration. For low volume or dilute samples, a smaller capacity (100 mg or 200 mg) suffices. Higher concentrations or larger sample volumes require higher capacity cartridges, such as 1 g or 2 g options.
Q: Where can POLYBOND C18-ne SPE Cartridges be purchased?
A: These cartridges are available through exporters, importers, manufacturers, suppliers, and traders in India. They can be sourced through laboratory supply companies or directly from the manufacturer.
Q: What makes the POLYBOND C18-ne SPE Cartridge suitable for automated extraction systems?
A: Its standard Luer tip connector allows easy integration with both manual and automated SPE setups, making it adaptable for various laboratory configurations and high-throughput workflows.
Q: How does the packing mass uniformity enhance extraction efficiency?
A: Excellent packing mass uniformity ensures consistent flow and reduced channeling, resulting in reliable reproducibility and optimal analyte recovery across batches and sample runs.
Q: What are the core components of this SPE cartridge?
A: Each cartridge consists of C18 bonded silica as the sorbent, a robust polypropylene cartridge body, and features a standard Luer tip for convenient connection to extraction apparatus.