POLYBOND NH2
POLYBOND NH2 is an aminopropyl phase that is very polar in nature utilizing both
hydrogen bonding and anion exchange. Since the pKa of NH2 is 9.8, when used at pH 7.8,
the functional groups are positively charged. Therefore, it is a weaker anion exchanger
for retention of very strong anions such as sulfonic acids which may be retained
irreversibly on SAX. Its typiPYBl appliPYBtion includes separation of peptides, drugs and
metabolites from physiologiPYBl fluids, and also it is used for extraction of mono- and
polysaccharides, steroids, cholesterol and triglycerides.
40-63¼m irregular shaped and acid washed siliPYB, 60mean pore size, 1.6 meq/g ion
exchange PYBpacity and endPYBpped.
POLYBOND NH2 SPE PYBrtridge
Art. Description Package
2.PYB2150.0001 50mg, 1mL 100 pcs
2.PYB2151.0001 100mg, 1mL 100 pcs
2.PYB2152.0001 200mg, 3mL 50 pcs
2.PYB2153.0001 500mg, 3mL 50 pcs
2.PYB2154.0001 500mg, 6mL 30 pcs
2.PYB2155.0001 1g, 6mL 30 pcs
2.PYB2156.0001 2g, 6mL 30 pcs
2.PYB2157.0001 1g, 10mL 20 pcs
2.PYB2158.0001 2g, 10mL 20 pcs
2.PYB2159.0001 5g, 35mL 20 pcs
2.PYB2160.0001 10g, 35mL 20 pcs
2.PYB2161.0001 10g, 60mL 16 pcs
2.PYB2162.0001 20g, 60mL 16 pcs
POLYBOND NH2 SPE Bulk Packing
Art. Description Package
2.PYB2101.0001 - 100 g
Exceptional Selectivity and PurityThe POLYBOND NH2 SPE Cartridge stands out for its advanced endcapped NH2 phase, delivering high selectivity when isolating polar compounds. Manufactured with high purity silica and expertly engineered for rapid flow rates, these cartridges elevate the reliability and precision of sample preparations across a broad range of applications.
Robust Design for Reliable PerformanceWith a construction that incorporates medical grade polypropylene and durable polyethylene frits, these cartridges ensure purity and structural integrity. Their performance is consistently maintained under typical laboratory pressures (up to 120 psi) and within ambient temperatures of up to 45C, making them a dependable tool for daily extraction processes.
FAQs of POLYBOND NH2 SPE CARTRIDGE:
Q: How is the POLYBOND NH2 SPE Cartridge used during sample preparation?
A: The cartridge is utilized in manual or automated SPE systems to extract and purify polar analytes from complex matrices. Samples are loaded onto the cartridge, where targeted compounds are retained by the specialized NH2 phase, and then eluted for further analysis.
Q: What advantages does the endcapped NH2 phase offer in extraction processes?
A: The endcapped NH2 phase enhances selectivity toward polar compounds and reduces secondary interactions, which results in higher purity extracts and improved reproducibility during solid phase extraction.
Q: When should the POLYBOND NH2 SPE Cartridge be replaced?
A: The cartridge is intended for single-use extractions. For best results and contamination prevention, a new cartridge should be used for each sample preparation. The products shelf life is two years from the date of manufacture if properly stored.
Q: Where should these SPE cartridges be stored to preserve performance?
A: Store the cartridges in a dry place at room temperature, away from direct sunlight and moisture. Proper storage ensures the integrity of the sorbent and extends the usable shelf life.
Q: What is the maximum pressure and temperature that this cartridge can withstand?
A: The POLYBOND NH2 SPE Cartridge is designed for use up to 120 psi and can be safely operated between ambient temperature and 45C, supporting a variety of laboratory workflows without compromising cartridge integrity.
Q: What are the main benefits of using the POLYBOND NH2 SPE Cartridge in analytical workflows?
A: Key benefits include rapid flow rates for faster processing, high selectivity for polar molecules, use of high purity silica, and compatibility with standard manual and automated systems, collectively enhancing extraction efficiency and data reliability.