Product Description
Smart Series
Indispensable in QC and R&D laboratories.
Features
Touch keyboard
Latest keyboarding technology, comfortable and easy to handle (6 keys)
Languages options
English / French / German / Catalan / Spanish / Italian / Japanese / Polish / Dutch / Portuguese
Program features
Time to Torque Time to Stop
Data displayed
Selected Speed
Selected Spindle
Viscosity readings (cP or mPa·s or cSt)
Percentage of Full Scale Range (%)
Sample Temperature (Optional, ºC or ºF)
Shear rate (with coaxial spindles) (s-1)
Shear Stress (with coaxial spindles) (N/m2)
Density (introduced by the user)(g/cm3)
Temperature reading by PT100
(Optional)
Universal adapter
All accessories
such as Brookfield
(Optional)
Graphic display
Provides huge range of graphical options
10 Working memories
Set up the unit and get it ready to be used every day choosing the memory you need
Viscosity readings
Absolute viscosity (cP or mPa·s)
Apparent Viscosity (cP or mPa·s)
Kinematic viscosity (cSt, mm2/sec)
(Density introduced by the user)
USB interface
Faster transfer data to the computer
Datalogger
(Software included)
USB allows data transfer to a Excel format
AUTO-TEST with sound and visual malfuction alarm
AUTO-ARANGE function
Other features
Time to torque: target torque pre-setting device.
Time to stop: target time pre-setting device.
Spindles
AISI 316 stainless steel spindles, easily identified by number and letter when changed according to range of viscosity.
These are the standards our units follow:
BS: 6075, 5350
ISO: 2555, 1652
ASTM: 115, 789, 1076, 1084, 1286, 1417, 1439, 1638, 1824, 2196, 2336, 2364, 2393, 2556, 2669, 2849, 2983, 2994, 3232, 3236, 3716
| Code | Model | Measuring Range (cP) | Speed (r.p.m) | Number of speeds |
| V200003 | SMART L | *1 - 2.000.000 | 0.3 - 100 | 18 |
| V200002 | SMART R | 100 - 13.000.000 | 0.3 - 100 | 18 |
| V200001 | SMART H | 200 - 106.000.000 | 0.3 - 100 | 18 |
Exceptional Accuracy and Measurement RangeThe Smart Series Viscometer guarantees top-notch precision with a 1.0% full-scale accuracy and a 0.01 mPas resolution, covering viscosities from 1 to 10,000,000 mPas. Its robust rotational mechanism, supported by four interchangeable spindles, makes it invaluable for quality control and research applications in laboratories and industry alike.
User-Friendly Interface and Advanced ConnectivityDesigned for seamless integration, this viscometer offers a digital LCD display for clear readings and supports both RS232 and USB connectivity. Data transfer and storage are straightforward, allowing for easy printing and exporting of test results to PCs and other digital systems, thus enhancing workflow efficiency.
Safety and Reliability for Every ApplicationSafety is prioritized with features like automatic overload alarms and over-temperature protection. The units durable build of stainless steel and ABS plastic ensures long-term resilience, while its power-efficient operation (<30W) and automated calibration (manual/auto) provide peace of mind for frequent laboratory and industrial use.
FAQs of Smart Series Viscometer:
Q: How does the Smart Series Viscometer enhance viscosity measurement accuracy?
A: The Smart Series Viscometer offers an accuracy of 1.0% of the full scale and a fine resolution of 0.01 mPas, supported by four standard spindles. This combination ensures reliable, repeatable measurements across a wide viscosity range, making it suitable for both routine and challenging laboratory analyses.
Q: What are the primary benefits of the Smart Series Viscometers connectivity options?
A: With RS232 and USB interfaces, this viscometer supports direct PC connectivity and data export. The print option allows for immediate results documentation, streamlining data handling and integration with laboratory information systems, which is particularly beneficial in high-throughput or regulated environments.
Q: When should you perform calibration on the Smart Series Viscometer, and how is it done?
A: Calibration is recommended upon installation, after any significant system change, or periodically as part of routine maintenance. The viscometer supports both manual and automatic calibration, with step-by-step on-screen instructions to ensure the device maintains accuracy over time.
Q: Where can the Smart Series Viscometer be used most effectively?
A: It is ideally suited for laboratory and industrial settings, including quality control laboratories, research institutes, and production facilities. Its ability to operate reliably at temperatures from 10C to 40C and humidity up to 80% ensures consistent performance in diverse environments.
Q: What is the process for measuring viscosity using this viscometer?
A: Users select the appropriate spindle and speed (0.1100 rpm), prepare a 1020 ml sample in the supplied borosilicate glass or stainless steel container, and follow the digital prompts on the LCD display. Data can be stored, printed, or transferred for further analysis, all within a streamlined workflow.
Q: How do the safety features of the Smart Series Viscometer benefit users?
A: Built-in overload alarms and over-temperature protection help safeguard both the operator and the instrument. These features reduce the risk of measurement errors and equipment damage, supporting safe and consistent operation for busy laboratory or industrial users.