Product Details:

  • Temperature Range Up to 360C
  • Core Components Test Cup, Thermometer, Flame Applicator, Heating Mechanism
  • Measurement Range 50C to 360C
  • Voltage 230 V AC
  • Automation Grade Manual
  • Accuracy 1C
  • Capacity Up to 500 ml (standard cup: 75 ml)
  • Click to view more
X

Flash And Fire Point Apparatus Price And Quantity

  • 5000 INR
  • 1 Piece

Flash And Fire Point Apparatus Product Specifications

  • Manual
  • 1C
  • Stainless Steel (Cup, Lid), Brass (Fittings), Mild Steel (Body)
  • Approx. 4.5 kg
  • Closed Cup (Abel/Pensky Martens/Fabricated)
  • Electricity (Mains operated)
  • Up to 500 ml (standard cup: 75 ml)
  • 50 Hz
  • Corrosion resistant, Easy cleaning, Sturdy base
  • 260 mm x 200 mm x 320 mm
  • Up to 360C
  • Test Cup, Thermometer, Flame Applicator, Heating Mechanism
  • 50C to 360C
  • 230 V AC

Flash And Fire Point Apparatus Trade Information

  • 5-10 Piece piece Per Month
  • 6-8 Week

Product Description

We are an internationally acclaimed trader and supplier of an exceptional range of Flash And Fire Point Apparatus. These apparatuses are used to define the hazards of flammable and combustible materials for shipping and safety regulations. Our Flash And Fire Point Apparatus are sourced from reliable vendors only after ensuring that, these are made from top quality materials. We offer these apparatuses at affordable prices within the stipulated time frame.

Features:

 

  • User friendly design
  • Compact design
  • Accurate measurement

Further Details: 

NATIONAL BRAND NAC100 FLASH AND FIRE POINT APPARATUS CLEVELAND OPEN CUP AS PER IP 36, ASTM D 92,IS 1448 (P-69) ELECTRICALLY HEATED MODELWITH VOLTAGE VARIAC WITH DIGITAL TEMP. INDICATOR



Reliable Laboratory Testing for Flash and Fire Points

Our Flash and Fire Point Apparatus is meticulously designed for researchers and quality control technicians in oil, gas, paint, and chemical sectors. It ensures precise determination of safety-critical properties by simulating ignition through a controlled flame and robust heating mechanism. Built to meet demanding international standards, the apparatus delivers consistent results and is trusted by laboratories and industrial facilities alike.


Robust Materials and Precise Graduation Markings

The apparatus incorporates a calibrated stainless steel test cup with clearly graduated volume markings, facilitating accurate sample measurement. All core componentsincluding the cup, lid, fittings, and bodyare constructed from corrosion-resistant materials such as stainless steel, brass, and powder-coated mild steel, ensuring durability and long-lasting performance.

FAQs of Flash And Fire Point Apparatus:


Q: How does the Flash and Fire Point Apparatus operate for sample testing?

A: The device tests samples by gradually heating them in a closed stainless steel cup while introducing an ignition source, such as a gas or spirit flame, at specified intervals using a manual flame applicator. The flash and fire points are recorded in accordance with IS 1448 (P21), ASTM D93, and IP34 methods.

Q: What types of materials can be tested with this apparatus?

A: This apparatus is suitable for testing petroleum and petroleum products, paints, solvents, and resins, making it widely applicable across laboratories and the oil & gas, paint, and chemical industries.

Q: When is it essential to use a calibration-certified Flash and Fire Point Apparatus?

A: Calibration certification is crucial whenever precise compliance with industry standards or regulatory requirements is needed, particularly for quality assurance testing in professional laboratories and industrial applications.

Q: Where can the Flash and Fire Point Apparatus be installed for optimal use?

A: Install the apparatus in a laboratory or designated industrial testing area with access to mains electricity and appropriate safety infrastructure. Its compact dimensions (260 mm x 200 mm x 320 mm) and sturdy base allow for secure placement on laboratory benches.

Q: What process does the apparatus follow for determining the flash and fire point?

A: The sample is measured using graduated markings, placed in the closed cup, and heated gradually with a variable regulator. At regular temperature intervals, the ignition flame is applied, and the flash and fire points are noted as per the relevant standard test method.

Q: What are the key benefits of using this apparatus in quality control?

A: Key advantages include high accuracy (1C), robust construction, corrosion resistance, easy cleaning, and reliable calibration, all of which contribute to dependable test results and adherence to global industry standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Flash And Fire Point Apparatus ' category



Back to top