Product Description
If your laboratory routinely requires ultra-sensitive detection limits from furnace analysis, the Thermo Scientific iCE 3400 AAS is ideal. This dedicated single Graphite Furnace AAS with both Deuterium and Zeeman background correction offers superb performance and value for money. Renowned Thermo Scientific SOLAAR software provides ultimate ease of use and analysis optimization; while our innovative Graphite Furnace Television (GFTV) gives a real time view of the cuvette as an aid to method development, ensuring accurate repeatable analysis
Maximize Productivity
This low cost Graphite Furnace AAS system, delivers a complete solution for laboratories facing challenging detection limits and needing elemental analysis by furnace.
- Dedicated furnace with parts-per-billion ultra-trace detection capability
- Six lamp auto-aligning carousel to maximize light through-put
- Run unattended, automated analysis with fully configurable auto-sampler
- SOLAAR software provides incredible support with wizards, optimization routines and automated performance controls
Gain Cost Efficiency
Gain even greater efficiency from hardware and accessories designed with cost control in mind.
- Innovative Extended Lifetime Cuvettes (ELC) for reduced consumable costs, can be used for thousands of firings
- Run analysis with just micro-liters of sample to minimize consumable consumption
- Gas flows with intelligent software controls keep usage low
GFTV real time viewing enables precise analysis, time after time
Enjoy Advanced Performance and Flexibility
All the innovation, performance and ease of use you expect from Thermo Scientific instruments come as standard with the iCE 3400 AAS.
- Guaranteed Deuterium and Zeeman background correction for high accuracy
- Vapour system and electrically heated cell can be utilised in this model
- Drift free results from automated cuvette heating control meaning, for accurate, repeatable analysis
Advanced Echelle optical system for precise measurements
Advanced Sensitivity and AutomationWith detection limits below 0.1 ppb for most elements and a fully automated gas control system, the iCE 3400 ensures high sensitivity and efficiency. Optional autosamplers and an automated sipper system streamline throughput for labs requiring high sample volumes, making it suitable for detailed and repeatable analyses.
Intuitive Interface and Robust SoftwareA 7-inch color touch-screen LCD display simplifies operation, while internal memory and seamless USB/LAN connectivity ensure flexible data management. Compatibility with Thermo Scientific SOLAAR software provides comprehensive control, compliance with CFR 21 Part 11, and advanced data handling capabilities.
Safety and Reliability for Diverse ApplicationsThe instrument incorporates multiple safety features, including automatic shutdown in case of gas leaks, over-temperature, or flame-out. Its corrosion-resistant metal housing and chemical-resistant components offer durability, meeting the rigorous demands of clinical, environmental, industrial, and food safety laboratories.
FAQs of iCE 3400 AAS Atomic Absorption Spectrometer :
Q: How do I introduce samples into the iCE 3400 Atomic Absorption Spectrometer?
A: The iCE 3400 supports both manual and automated sample introduction. It comes with a sipper and offers an optional autosampler that can accommodate up to 240 positions, efficiently handling large sample batches automatically for high-throughput analyses.
Q: What types of analyses can be performed on the iCE 3400?
A: This instrument is suitable for an array of applications such as trace heavy metal detection, clinical chemistry, environmental monitoring, and food and beverage analysis, utilizing its multiple reading modes including Flame AAS, Graphite Furnace AAS, and Vapor Generation.
Q: When should I use the nitrous oxide-acetylene flame instead of air-acetylene?
A: The nitrous oxide-acetylene flame is typically used when higher flame temperatures are necessary, especially for analyzing refractory elements that require greater energy to achieve proper atomization and accurate measurement.
Q: Where is the data from my analyses stored and how can I access it?
A: All data can be stored internally on the instrument. For convenience and further analysis, users can transfer data via USB or LAN to compatible computers, and manage results using Thermo Scientific SOLAAR software.
Q: What is the process for ensuring safety during operation?
A: The instrument features automatic shutdown protocols in the event of a gas leak, flame-out, or excessive temperature. Built-in sensors and robust material construction also help prevent operational hazards, providing a safe working environment.
Q: How does the iCE 3400 benefit high-volume laboratories?
A: With high sensitivity, fast analysis speeds, and automation options such as a large-capacity autosampler and advanced software, the instrument significantly improves efficiency and repeatability in laboratories handling frequent, large-scale elemental analyses.