Product Description
The ULUF 590 freezer -90°C features a dual refrigeration system which consists of two independent systems offering you the best security.
Main features
- Dual refrigeration system
- Insulated inner doors
- Castors
- Lock on door
- Ergonomic loading
- Heated door frame
- Heated vacuum valve
- 100% HCFC/CFC free
- Reaching -90°C in 3 hours
- Porthole for external probe
Model info
| Temperature range (°C) | -90 / -40 |
| Max. ambient temperature (°C) | 25 C / 77 F |
| Power supply (V) | 230 |
| Frequency (Hz) | 50/60 |
| Power consumption (KWH/24H) | 15,7 |
| Power (Watt) | 1300 |
| Horse Power (HP): | 2 x 3/4 |
| Current (A) | 8,9 |
Controller features
| Visual / Acoustic Alarm | check |
| Power failure alarm | check |
| Ajustable high/low temperature alarm | check |
| Low battery alarm | check |
| Compressor alarm | check |
| Open door alarm | check |
| Probe failure alarm | check |
| Alarm display as text - not codes | check |
| Contact for remote alarm | check |
| Prepared for GSM alarm module | check |
| Hours of battery backup | 72 |
| Digital display | check |
| Data logger | check |
| RS 232 interface | check |
| RS 485 interface | check |
| USB | check |
| Defrost technology | Manual |
| Chart recorder | Optional |
Bodywork
| Shelves (pcs) / drawers (pcs) | 4 / -(*) |
| Adjustable Shelves (pcs) / drawers (pcs) | no |
| Basket | remove |
| Sub lids / doors (pcs) | - / 5 |
| Lighting | check |
| Castors | check |
| Lock | check |
| Inner liner material | Stainless steal |
| Cabinet material | Varnished steel |
| Colour (exterior) | White |
| Number of compressors | 2 |
| Refrigerant | EP 88 |
Shipping information
| Weight (KG) | 242 |
| Shipping weight (KG) | 342 |
| Shipping weight with wooden crate (KG) | 342 |
| Shipping dimensions WxDxH (mm) | 1020x1070x2310 |
| Shipping dimensions with wooden box (WxDxH) (mm) | 1030x965x2208 |
| Shipping M3 | 2,52 |
| Rack model | Box size (height mm) | Rack model and total quantity | No. of boxes pr. rack | Total no. of boxes | Exterior dimensions of rack (WxDxH mm) | |
| Upright drawer rack | 50 | 20 x UDR50-44 | 4 x 4 | 320 | 140 x 567 x 231 | |
| Upright drawer rack | 75 | 20 x UDR75-42 | 4 x 2 | 160 | 140 x 567 x 163 | |
| Upright drawer rack | 100 | 20 x UDR100-42 | 4 x 2 | 160 | 140 x 558 x 214 | |
| Upright side rack | 50 | 20 x USR50-44 | 4 x 4 | 320 | 139 x 549 x 224 | |
Energy-Efficient Ultra Low Temperature CoolingEngineered for reliability, the ULUF 590-2M consumes just 13.2 kWh/24h, making it an energy-conscious choice for continuous use. Direct cooling technology maintains stable internal conditions even during frequent door openings, ideal for critical samples. The microprocessor with LED display ensures precise control and effortless monitoring.
Advanced Safety and Alarm SystemsProtect valuable samples with comprehensive alarmsincluding power failure, high/low temperature, filter, and door alerts. Audible and visible indicators provide immediate notifications, allowing prompt corrective actions. The standard door lock and key ensure contents remain secure at all times.
User-Friendly Data ManagementA built-in data logger with USB export simplifies documentation and regulatory compliance requirements. Easy access to performance records streamlines routine audits, while the digital display allows real-time temperature readings. Maintenance processes are hassle-free thanks to manual defrost and removable shelving.
FAQs of Arctiko ULUF 590-2M:
Q: How does the Arctiko ULUF 590-2M maintain ultra low temperatures effectively?
A: The freezer uses direct cooling technology alongside robust insulation and a microprocessor-controlled system to maintain temperatures from -86C to -60C, ensuring uniform and reliable storage conditions for sensitive medical and laboratory materials.
Q: What safety features help protect samples in the ULUF 590-2M?
A: It is equipped with an advanced alarm system for power failure, high/low temperature, filter, and door events. Audible and visible alarms alert users immediately, while a standard lock with a key adds another layer of security for stored samples.
Q: When should I use the built-in data logger, and how does it work?
A: Use the built-in data logger whenever you need to export temperature and event records. It continuously logs data and allows for easy extraction via USB, making documentation and audits straightforward.
Q: Where can the ULUF 590-2M be utilized?
A: This ultra low temperature freezer is suitable for use in medical facilities, research institutes, and laboratories across India, and is available from exporters, importers, manufacturers, suppliers, and traders.
Q: What is the process for defrosting the freezer?
A: The ULUF 590-2M uses manual defrosting. To defrost, temporarily relocate stored items, switch off the unit, and allow the ice to melt. Clean and dry the interior thoroughly before returning the samples.
Q: How does the freezer benefit laboratory operations?
A: With its large capacity, energy efficiency, secure storage, and advanced monitoring features, the freezer ensures reliable preservation of specimens, supporting compliance and continuity in demanding laboratory workflows.