08045815658
info@nationalsales.co
Change Language
SILICONE VISCOSITY STANDARDS

SILICONE VISCOSITY STANDARDS

Product Details:

  • Accuracy 1% of stated viscosity value
  • Feature Certified kinematic viscosity, traceable to NIST
  • Temperature Range Available for use at 23C or custom as per request
  • Capacity 500 mL, 1 Liter, 2.5 Liters, 5 Liters (as per requirement)
  • Model No SVS Series
  • Automation Grade Manual (ingredient/solution based)
  • Core Components Silicone Viscosity Standard Solution
  • Click to view more
X

SILICONE VISCOSITY STANDARDS Price And Quantity

  • 5000 INR
  • 1 Piece

SILICONE VISCOSITY STANDARDS Product Specifications

  • Silicone Viscosity Standard Solution
  • A wide range from 20 cSt to 100,000 cSt available
  • High-Purity Silicone Oils, Supplied in Glass Bottles
  • Not Applicable (Chemical Standard)
  • Approximate to bottle size; e.g., 1 Liter ~970g
  • Viscosity Standard (Silicone Oil Base)
  • 1% of stated viscosity value
  • Calibration and verification of viscometers and rheometers
  • Certified kinematic viscosity, traceable to NIST
  • Available for use at 23C or custom as per request
  • Varies as per bottle volume (typical: 1L bottle 9cm x 9cm x 24cm)
  • 500 mL, 1 Liter, 2.5 Liters, 5 Liters (as per requirement)
  • SVS Series
  • Manual (ingredient/solution based)
  • Not Applicable (Standard Chemical Solution)

SILICONE VISCOSITY STANDARDS Trade Information

  • 5-10 Piece piece Per Month
  • 6-8 Week

Product Description

They are indispensable to verify and perform calibration of our rotary viscometers.

Supplied in 600 ml containers perfectly suitable to perform calibration procedures without the need to transfer calibration fluid to a test beaker.

Accuracy 1% of viscosity value and excellent temperature stability.

Standard silicone oils are certified to international standards.

Corresponding calibration certificates supplied together indicate viscosity values at 20ºC and 25ºC. We recommend using for the calibration of our instruments the value at 25ºC.

One or two silicone standards should be sufficient to verify calibration of instrument.

Code Aproximate viscosity in mPas at 25
CAL-RT5 5 mPas
CAL-RT10 10 mPas
CAL-RT50 50 mPas
CAL-RT75 75 mPas
CAL-RT100 100 mPas
CAL-RT250 250 mPas
CAL-RT350 350 mPas
CAL-RT500 500 mPas
CAL-RT1K 1.000 mPas
CAL-RT5K 5.000 mPas
CAL-RT10K 10.000 mPas
CAL-RT12K 12.500 mPas
CAL-RT30K 30.000 mPas
CAL-RT60K 60.000 mPas
CAL-RT100K 100.000 mPas

 



Reliable Calibration Standards for Precise Results

Our Silicone Viscosity Standards are formulated to maintain high purity and stability, making them the preferred choice for laboratories and industries requiring certified accuracy. Packaged securely in glass or HDPE bottles, these standards adhere to global quality regulations and are suitable for a range of viscometers and rheometers. Consistent viscosity and traceability ensure reliability in every use.


Versatile Packaging and Measurement Range

Meeting various requirements, SVS Series standards are available in capacities from 500 mL up to 5 Liters and a wide viscosity range (20 cSt to 100,000 cSt). Suitable for diverse testing protocols, each bottle is clearly labeled and tamper-sealed, preserving integrity and ensuring ease of storage and handling.


User Guidelines for Optimal Performance

For best results, store the standards in a tightly closed container, away from heat and direct sunlight. Annual recalibration is advised or as specified by your SOP. Unopened containers offer a shelf life of 1224 months, providing extended usability and value.

FAQs of SILICONE VISCOSITY STANDARDS:


Q: How should Silicone Viscosity Standards be stored for optimal shelf life?

A: Keep the standards in their original, tightly closed containers, placed away from heat sources and direct sunlight to preserve their integrity and extend shelf life to 1224 months.

Q: What is the process for using these standards to calibrate viscometers?

A: To calibrate, transfer the required volume into a clean test vessel, equilibrate to the specified temperature (e.g., 23C), and follow your instruments calibration procedure as outlined in the operating manual or SOP.

Q: When is recalibration of Silicone Viscosity Standards recommended?

A: Annual recalibration is recommended, or more frequently if stipulated by your standard operating procedures or regulatory requirements.

Q: What equipment are these viscosity standards compatible with?

A: They are compatible with a broad range of viscometers and rheometers, including those from Brookfield, Fungilab, Anton Paar, Sheen, and other leading brands.

Q: Where are these standards commonly used?

A: Silicone Viscosity Standards are widely employed in quality control laboratories, research facilities, and industrial settings across sectors needing reliable viscosity measurements, such as paints, coatings, lubricants, and chemicals.

Q: What are the benefits of using certified silicone viscosity standards?

A: Using certified standards ensures traceability to NIST values, provides accuracy within 1%, and supports compliance with industry regulations, ultimately improving the reliability of your viscosity measurements.

Q: Can I request custom viscosity or temperature specifications?

A: Yes, custom viscosity or temperature ranges can be supplied upon request to meet specific application needs.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number